BV786 Mouse Anti-Human CD86
Product Details
Down Arrow Up Arrow


BD OptiBuild™
B7.2; B7-2; B-lymphocyte activation antigen B7-2; B70; CD28LG2; LAB72
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Human ARH 77 Cell Line
Flow cytometry (Qualified)
0.2 mg/ml
V BP072, A109; VI BP95, CD86.9
AB_2744102
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV786 under optimal conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes (including BD OptiBuild Brilliant reagents) are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794).

Product Notices

  1. This antibody was developed for use in flow cytometry.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Researchers should determine the optimal concentration of this reagent for their individual applications.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. BD Horizon Brilliant Violet 786 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,455,613; 8,575,303; 8,354,239.
  10. Cy is a trademark of GE Healthcare.
747526 Rev. 1
Antibody Details
Down Arrow Up Arrow
BU63

The BU63 monoclonal antibody specifically recognizes CD86 which is also known as B70, B7-2, B7.2, LAB72 or CD28LG2. CD86 is a ~70-80 kDa type I transmembrane glycoprotein that belongs to the Ig gene superfamily. CD86 is expressed on monocytes, dendritic cells, Langerhans cells, activated B cells, and memory B cells. Like CD80 (B7-1), CD86 serves as a ligand for CD28 or CD152 (CTLA-4) expressed by T cells and can induce costimulatory or coinhibitory signals, respectively. The BU63 antibody can reportedly block the binding of other human CD86-specific antibodies including the 2331 (FUN-1) (complete block) or IT2.2 (partial block) antibodies. These results suggest that the BU63 antibody may bind to a similar or identical CD86 epitope as the 2331 (FUN-1) antibody but to a different, although spatially-related epitope compared with the IT2.2 antibody.

The antibody was conjugated to BD Horizon™ BV786 which is part of the BD Horizon Brilliant™ Violet family of dyes. This dye is a tandem fluorochrome of BD Horizon BV421 with an Ex Max of 405-nm and an acceptor dye with an Em Max at 786-nm.  BD Horizon BV786 can be excited by the violet laser and detected in a filter used to detect Cy™7-like dyes (eg, 780/60-nm filter).

747526 Rev. 1
Format Details
Down Arrow Up Arrow
BV786
The BD Horizon Brilliant Violet™ 786 (BV786) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an Ex Max of 407-nm and an acceptor dye with an Em Max at 786-nm.  BV786, driven by BD innovation, is designed to be excited by the violet laser and detected using a filter, centered near 785 nm (e.g. 780/60 nm bandpass filter).  Please ensure that your instrument’s configurations (lasers and filters) are appropriate for this dye.
altImg
BV786
Violet 405 nm
407 nm
786 nm
747526 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "747526" on CiteAb

Development References (6)

  1. Azuma H, Uno Y, Shigekiyo T, Saito S. Congenital plasminogen deficiency caused by a Ser572 to Pro mutation. Blood. 1993; 82(2):475-480. View Reference
  2. Azuma M, Ito D, Yagita H, et al. B70 antigen is a second ligand for CTLA-4 and CD28.. Nature. 1993; 366(6450):76-9. View Reference
  3. Du X, Nagata S, Ise T, Stetler-Stevenson M, Pastan I. FCRL1 on chronic lymphocytic leukemia, hairy cell leukemia, and B-cell non-Hodgkin lymphoma as a target of immunotoxins.. Blood. 2008; 111(1):338-43. (Immunogen: Cytotoxicity, Flow cytometry, Functional assay). View Reference
  4. Engel P, Gribben JG, Freeman GJ, et al. The B7-2 (B70) costimulatory molecule expressed by monocytes and activated B lymphocytes is the CD86 differentiation antigen. Blood. 1994; 84(5):1402-1407. View Reference
  5. Llinas L, Lazaro A, de Salort J, Matesanz-Isabel J, Sintes J, Engel P. Expression profiles of novel cell surface molecules on B-cell subsets and plasma cells as analyzed by flow cytometry. Immunol Lett. 2011; 134(2):113-121. (Biology). View Reference
  6. Matesanz-Isabel J, Sintes J, Llinas L, de Salort J, Lazaro A, Engel P. New B-cell CD molecules. Immunol Lett. 2011; 134(2):104-112. (Biology). View Reference
View All (6) View Less
747526 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.