Anti-Lambda APC-H7
Product Details
Down Arrow Up Arrow


BD™
IGL; IGL@; Ig λ; Immunoglobulin lambda
Human
Mouse BALB/c IgG1, λ
Human IgA1-λ myeloma Protein
Flow cytometry
100 μg/mL
5 μL
3535,931
Phosphate buffered saline with BSA and ProClin®.
ASR


Preparation And Storage

Store vials at 2°C–8°C. Conjugated forms should not be frozen. Protect from exposure to light. Each reagent is stable until the expiration date shown on the bottle label when stored as directed.

656157 Rev. 1
Antibody Details
Down Arrow Up Arrow
1-155-2

The Anti-Lambda antibody, clone 1-155-2, is derived from the hybridization of P3-X63-Ag8.653 mouse myeloma cells with cells from BALB/cJ mice immunized with human IgA1-λ myeloma protein.

The Anti-Lambda antibody specifically recognizes lambda light chains of human immunoglobulins.

656157 Rev. 1
Format Details
Down Arrow Up Arrow
APC-H7
The BD Horizon™ APC-H7 dye is a part of the BD APC red family of dyes. This tandem fluorochrome is comprised of a Allophycocyanin (APC) donor that has excitation maxima (Ex Max) of 659 nm and an acceptor dye, H7, with an emission maximum (Em Max) at 782 nm. APC-H7, driven by BD innovation, is designed to be excited by the Red (627-640 nm) laser and detected using an optical filter centered near 780 nm (e.g., a 760/60 nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
APC-H7
Red 627-640 nm
659 nm
782 nm
656157 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "656157" on CiteAb

Development References (12)

  1. Ault KA. Flow cytometric evaluation of normal and neoplastic B cells. In: Rose NR, Friedman H, Fahey JL. Rose NR, Friedman H, Fahey JL, ed. Manual of Clinical Laboratory Immunology. 3rd ed.. Washington, DC: American Society for Microbiology; 1986:247-253. View Reference
  2. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in healthcare settings. MMWR. 1988; 37:377-388. (Biology).
  3. Clinical and Laboratory Standards Institute. 2005. (Biology).
  4. Foon KA, Todd RF. Immunologic classification of leukemia and lymphoma.. Blood. 1986; 68(1):1-31. (Biology). View Reference
  5. Harris NL, Data RE. The distribution of neoplastic and normal B-lymphoid cells in nodular lymphomas: use of an immunoperoxidase technique on frozen sections.. Hum Pathol. 1982; 13(7):610-7. (Biology). View Reference
  6. Kubagawa H, Gathings WE, Levitt D, Kearney JF, Cooper MD. Immunoglobulin isotype expression of normal pre-B cells as determined by immunofluorescence.. J Clin Immunol. 1982; 2(4):264-9. (Biology). View Reference
  7. Meis JM, Osborne BM, Butler JJ. A comparative marker study of large cell lymphoma, Hodgkin's disease, and true histiocytic lymphoma in paraffin-embedded tissue.. Am J Clin Pathol. 1986; 86(5):591-9. (Biology). View Reference
  8. Picker LJ, Weiss LM, Medeiros LJ, Wood GS, Warnke RA. Immunophenotypic criteria for the diagnosis of non-Hodgkin's lymphoma.. Am J Pathol. 1987; 128(1):181-201. (Biology). View Reference
  9. Smith BR, Weinberg DS, Robert NJ, et al. Circulating monoclonal B lymphocytes in non-Hodgkin's lymphoma.. N Engl J Med. 1984; 311(23):1476-81. (Biology). View Reference
  10. Tubbs RR, Sheibani K, Weiss RA, Sebek BA, Deodhar SD. Tissue immunomicroscopic evaluation of monoclonality of B-cell lymphomas: comparison with cell suspension studies.. Am J Clin Pathol. 1981; 76(1):24-8. (Biology). View Reference
  11. Têtu B, Manning JT, Ordóñez NG. Comparison of monoclonal and polyclonal antibodies directed against immunoglobulin light and heavy chains in non-Hodgkin's lymphoma.. Am J Clin Pathol. 1986; 85(1):25-31. (Biology). View Reference
  12. Weinberg DS, Pinkus GS, Ault KA. Cytofluorometric detection of B cell clonal excess: a new approach to the diagnosis of B cell lymphoma.. Blood. 1984; 63(5):1080-7. (Biology). View Reference
View All (12) View Less
656157 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For In Vitro Diagnostic Use.

 

23-22942-00

Analyte Specific Reagent. Analytical and performance characteristics are not established.

 

Documents are subject to revision without notice. Please verify you have the correct revision of the document, and always refer back to BD's eIFU website for the latest and most up to date information.