Your selected country is
United States
- Change country/language
-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® OMICS-One Immune Profiler Protein Panel
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
-
- BD® OMICS-Guard Sample Preservation Buffer
- BD® AbSeq Assay
- BD® OMICS-One Immune Profiler Protein Panel
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- United States (English)
- Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Two-color flow cytometric analysis of CD317 (BST2) expression on mouse splenocytes. SJL mouse spleen cells were stained with Alexa Fluor® 647 Rat Anti-Mouse CD45R/B220 antibody (Cat. No. 557683) and either BD Horizon™ BV421 Rat IgG2b, κ Isotype Control (Cat. No. 562603; Left Plot) or BD Horizon BV421 Rat Anti-Mouse CD317 (BST2) antibody (Cat. No. 566431; Right Plot) at 0.06 μg/test. Two-color flow cytometric dot plots showing the correlated expression of CD45R/B220 versus CD317 (BST2) [or Ig Isotype control staining] were derived from gated events with the forward and side light-scatter characteristics of viable mononuclear cells. Flow cytometric analysis was performed using a BD LSRFortessa™ Cell Analyzer System. Data shown on this Technical Data Sheet are not lot specific.
BD Horizon™ BV421 Rat Anti-Mouse CD317 (BST2)
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
For optimal and reproducible results, BD Horizon Brilliant™ Stain Buffer should be used anytime BD Horizon Brilliant™ dyes are used in a multicolor flow cytometry panel. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- An isotype control should be used at the same concentration as the antibody of interest.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Pacific Blue™ is a trademark of Molecular Probes, Inc., Eugene, OR.
- BD Horizon Brilliant Violet 421 is covered by one or more of the following US patents: 8,158,444; 8,362,193; 8,575,303; 8,354,239.
- BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
Companion Products
The 927 monoclonal antibody specifically recognizes CD317 which is also known as Bone marrow stromal antigen 2 (BST2) or Plasmacytoid Dendritic Cell Ag-1 (PDCA-1). CD317 (BST2) is a type II transmembrane glycoprotein that is encoded by Bst2. It is highly expressed on naïve plasmacytoid dendritic cells (pDC) which comprise very small populations within lymphoid and nonlymphoid tissues. pDC are characteristically early responders to viruses through Toll-like receptors (TLR), TLR7 and TLR9. Activated pDC can produce large amounts of proinflammatory cytokines including type I interferons, Interferon-alpha (IFN-α) and Interferon-beta (IFN-β), and are also known as Type I IFN producing cells (IPC). CD317 (BST2) expression can be upregulated on a variety of other cell types following stimulation with type I IFNs and IFN gamma including T cells, B cells, plasma cells, NK cells, CD8+ and CD8- dendritic cells, and cell lines. CD317 (BST2) may play a role in sorting proteins, eg, cytokines, from the Golgi apparatus and the plasma membrane.
Development References (2)
-
Blasius AL, Giurisato E, Cella M, Schreiber RD, Shaw AS, Colonna M. Bone marrow stromal cell antigen 2 is a specific marker of type I IFN-producing cells in the naive mouse, but a promiscuous cell surface antigen following IFN stimulation.. J Immunol. 2006; 177(5):3260-5. (Immunogen: Flow cytometry, Fluorescence microscopy, Immunofluorescence). View Reference
-
Ohtomo T, Sugamata Y, Ozaki Y, et al. Molecular cloning and characterization of a surface antigen preferentially overexpressed on multiple myeloma cells. Biochem Biophys Res Commun. 1999; 258(3):583-591. (Biology). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.