Flow cytometric analysis of CD31 expression on human peripheral blood leucocyte populations. Whole blood was stained with either BD Horizon™ BV480 Mouse IgG1, κ Isotype Control (Cat. No. 565652; Left Plot) or BD Horizon BV480 Mouse Anti-Human CD31 antibody (Cat. No. 566144/566195; Right Plot). Erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). Two-parameter flow cytometric contour plots showing the correlated expression of CD31 (or Ig Isotype control staining) versus side-light scatter (SSC-A) signals were derived from gated events with the forward and side light-scatter signals of intact leucocyte populations. Flow cytometric analysis was performed using a BD LSRFortessa™ Cell Analyzer System.
Flow cytometric analysis of CD31 expression on human peripheral blood leucocyte populations. Whole blood was stained with either BD Horizon™ BV480 Mouse IgG1, κ Isotype Control (Cat. No. 565652; Left Plot) or BD Horizon BV480 Mouse Anti-Human CD31 antibody (Cat. No. 566144/566195; Right Plot). Erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). Two-parameter flow cytometric contour plots showing the correlated expression of CD31 (or Ig Isotype control staining) versus side-light scatter (SSC-A) signals were derived from gated events with the forward and side light-scatter signals of intact leucocyte populations. Flow cytometric analysis was performed using a BD LSRFortessa™ Cell Analyzer System.
Product Details
Down Arrow Up Arrow


BD Horizon™
EndoCAM; GPIIA'; PECA1; PECAM1; Platelet endothelial cell adhesion molecule
Human (QC Testing), Rhesus, Cynomolgus, Baboon (Tested in Development)
Mouse IgG1, κ
Flow cytometry (Routinely Tested)
5 µl
V P025
5175
AB_2739542
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV480 under optimum conditions, and unconjugated antibody and free BD Horizon BV480 were removed.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

For Immunofluorescence Applications:

The use of a mounting reagent (eg, ProLong® Gold) is highly recommended to maximize the photostability of BV480.  For confocal microscopy systems, a 440 nm laser is the optimal excitation source and the recommended emission filter is a 485/20 nm bandpass filter.  

For epifluorescence microscopes with broad spectrum excitation sources,  the recommended excitation and emission filters are 445/20 nm and 485/20 nm bandpass filters, respectively.  For specific multicolor imaging applications, the exact filter configurations should be optimized by the end user. For additional instrument/filter configuration information, please visit http://www.bdbiosciences.com/research/cellularimaging.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  5. BD Horizon Brilliant Violet 480 is covered by one or more of the following US patents: 8,575,303; 8,354,239.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. BD Horizon Brilliant Violet 480 is covered by one or more of the following US patents: 8,575,303; 8,354,239.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  10. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
Antibody Details
Down Arrow Up Arrow
WM59

The WM59 monoclonal antibody specifically binds to platelet endothelial cell adhesion molecule-1, (PECAM-1, PECAM1), which is also known as GPIIA', or EndoCAM. CD31 is a 130 kDa type I transmembrane glycoprotein that belongs to the Ig gene superfamily.  CD31 has wide tissue distribution and is expressed on platelets, monocytes, granulocytes, NK cells, T cell subsets, and in high amounts on endothelial cells. CD31 functions as a vascular endothelial cell adhesion molecule and is involved in the transendothelial migration of leucocytes in inflammatory responses. It might be involved in thrombosis, angiogenesis, and wound healing. The WM59 appears to recognize an epitope proximal to extracellular domain 2 of CD31.

Clone WM59 also cross-reacts with peripheral blood platelets and leukocytes of baboon, and both rhesus and cynomolgus macaque monkeys. The staining intensity of WM59+ platelets is similiar to that observed with peripheral blood platelets from normal human donors. Lymphocytes, monocytes, and granulocytes react less with WM59 than normal human leukocytes.

The antibody was conjugated to BD Horizon BV480 which is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 436-nm and Em Max at 478-nm, BD Horizon BV480 can be excited by the violet laser and detected in the BD Horizon BV510 (525/40-nm) filter set.  BV480 has less spillover into the BV605 detector and, in general, is brighter than BV510.

Format Details
Down Arrow Up Arrow
BV480
The BD Horizon Brilliant Violet™ 480 (BV480) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This polymer-technology fluorochrome has an excitation maximum (Ex Max) of 440-nm and an emission maximum (Em Max) of 479-nm. Driven by BD innovation, BV480 is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 480-nm (e.g., a 525/50 bandpass filter). The increased fluorescence intensity of BV480 and narrower emission spectra, make it a good alternative for BV510 or V500. Due to its excitation profile, BV480 will also has less cross-laser excitation with the UV laser, resulting in less spillover into UV channels compared to BV510. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV480
Violet 405 nm
440 nm
479 nm
Citations & References
Down Arrow Up Arrow
View product citations for antibody "566144" on CiteAb

Development References (6)

  1. DeLisser HM, Newman PJ, Albelda SM. Platelet endothelial cell adhesion molecule (CD31). Curr Top Microbiol Immunol. 1993; 184:37-45. (Biology). View Reference
  2. Fawcett J, Buckley C, Holness CL, et al. Mapping the homotypic binding sites in CD31 and the role of CD31 adhesion in the formation of interendothelial cell contacts. J Cell Biol. 1995; 128(6):1229-1241. (Clone-specific: Blocking, ELISA). View Reference
  3. Lin G-X, Yang X, Hollemweguer E, et al. Cross-reactivity of CD antibodies in eight animal species. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:519-523.
  4. Muller WA, Weigl SA, Deng X, Phillips DM. PECAM-1 is required for transendothelial migration of leukocytes. J Exp Med. 1993; 178(2):449-460. (Biology). View Reference
  5. Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995.
  6. Vaporciyan AA, DeLisser HM, Yan HC, et al. Involvement of platelet-endothelial cell adhesion molecule-1 in neutrophil recruitment in vivo.. Science. 1993; 262(5139):1580-2. (Biology). View Reference
View All (6) View Less

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.