PE Mouse Anti-Human Blood Group A
PE Mouse Anti-Human Blood Group A
Flow cytometric analysis of Human Blood Group A expression on human red blood cells. Human red blood cells were stained with either PE Mouse IgG3, κ Isotype Control (Cat. No. 556659; dashed line histogram) or PE Mouse Anti-Human Blood Group A antibody (Cat. No. 565385; solid line histogram).  The fluorescence histogram showing Human Blood Group A expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes. Flow cytometric analysis was performed using a BD™ LSR II Flow Cytometer System.
Flow cytometric analysis of Human Blood Group A expression on human red blood cells. Human red blood cells were stained with either PE Mouse IgG3, κ Isotype Control (Cat. No. 556659; dashed line histogram) or PE Mouse Anti-Human Blood Group A antibody (Cat. No. 565385; solid line histogram).  The fluorescence histogram showing Human Blood Group A expression (or Ig Isotype control staining) was derived from gated events with the forward and side light-scatter characteristics of erythrocytes. Flow cytometric analysis was performed using a BD™ LSR II Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Human (QC Testing)
Mouse IgG3, κ
Flow cytometry (Routinely Tested)
5 µl
AB_2739211
Aqueous buffered solution containing BSA, protein stabilizer, and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
565385 Rev. 1
Antibody Details
Down Arrow Up Arrow
NaM87-1F6

The NaM87-1F6 monoclonal antibody specifically binds to blood group A expressed on human erythrocytes. Clone NaM87-1F6 induces agglutination of human group A red blood cells. It does not react with human group B, or group O red blood cells.

                

565385 Rev. 1
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
565385 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "565385" on CiteAb

Development References (3)

  1. Blanchard D, Bruneau V, Bernard D, et al. Flow cytometry analysis of dual red blood cell populations after bone marrow transplantation. Br J Haematol. 1995; 89(4):741-747. (Clone-specific: Flow cytometry). View Reference
  2. David B, Bernard D, Navenot JM, Muller JY, Blanchard D. Flow cytometric monitoring of red blood cell chimerism after bone marrow transplantation. Transfus Med. 1999; 9(3):209-217. (Clone-specific: Flow cytometry).
  3. Walker RH, ed. Technical Manual of the American Association of Blood Banks. Arlington VA: 1990.
565385 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.