BB515 Mouse Anti-Human CD7
BB515 Mouse Anti-Human CD7
Flow cytometric analysis of CD7 expression on human peripheral blood lymphocytes - Staining comparisons between BD Horizon™ BB515- and FITC-conjugated antibodies. Human whole blood was stained with either BD Horizon BB515 Mouse IgG1, κ Isotype Control (Cat. No. 564416; dashed line histogram) or BD Horizon BB515 Mouse Anti-Human CD7 antibody (Cat. No. 565211; bold solid line histogram). Alternatively, cells were stained with FITC Anti-Human CD7 antibody (Cat. No. 555360/561933; thin solid line histogram). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202).        Overlaid histograms are shown to facilitate staining comparisons between: BB515 Anti-CD7 antibody versus its Ig Isotype Control (Left Panel), or BB515 Anti-CD7 antibody versus FITC Anti-CD7 antibody (Right Panel). The fluorescence histograms showing CD7 expression (or Ig Isotype control staining) were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometric analysis was performed using a BD LSRFortessa™ Cell Analyzer System.
Flow cytometric analysis of CD7 expression on human peripheral blood lymphocytes - Staining comparisons between BD Horizon™ BB515- and FITC-conjugated antibodies. Human whole blood was stained with either BD Horizon BB515 Mouse IgG1, κ Isotype Control (Cat. No. 564416; dashed line histogram) or BD Horizon BB515 Mouse Anti-Human CD7 antibody (Cat. No. 565211; bold solid line histogram). Alternatively, cells were stained with FITC Anti-Human CD7 antibody (Cat. No. 555360/561933; thin solid line histogram). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202).        Overlaid histograms are shown to facilitate staining comparisons between: BB515 Anti-CD7 antibody versus its Ig Isotype Control (Left Panel), or BB515 Anti-CD7 antibody versus FITC Anti-CD7 antibody (Right Panel). The fluorescence histograms showing CD7 expression (or Ig Isotype control staining) were derived from gated events with the forward and side light-scatter characteristics of intact lymphocytes. Flow cytometric analysis was performed using a BD LSRFortessa™ Cell Analyzer System.
Product Details
Down Arrow Up Arrow


BD Horizon™
GP40; LEU-9; T-cell leukemia antigen; Tp40; TP41
Human (QC Testing)
Mouse BALB/c IgG1, κ
P-CLL and Jurkat Cells
Flow cytometry (Routinely Tested)
5 µl
IV T163
924
AB_2739113
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon™ BB515 under optimum conditions and unconjugated antibody was removed.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

For optimal results, it is recommended to perform 2 washes after staining with antibodies. Cells may be prepared, stained with antibodies and washed twice with wash buffer per established protocols for immunofluorescence staining, prior to acquisition on a flow cytometer. Performing fewer than the recommended wash steps may lead to increased spread of the negative population.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
565211 Rev. 2
Antibody Details
Down Arrow Up Arrow
M-T701

The M-T701 monoclonal antibody specifically binds to CD7. CD7 is a 40 kDa type I transmembrane glycoprotein that belongs to the immunoglobulin superfamily.  The CD7 antigen is also known as Leu-9, TP41, Tp40, GP40, and T-cell leukemia antigen. It is expressed on thymocytes, T cells, pre-B cells, and NK cells. CD7 is present in reduced density on monocytic cells and cell lines. Functional studies demonstrate that crosslinking of the CD7 can induce transmembrane calcium flux in T cells.

The antibody was conjugated to BD Horizon BB515 which is part of the BD Horizon Brilliant™ Blue family of dyes. With an Ex Max near 490 nm and an Em Max near 515 nm, BD Horizon BB515 can be excited by the blue laser (488 nm) laser and detected with a 530/30 nm filter. This dye has been exclusively developed by BD Biosciences and is up to seven times brighter than FITC with less spillover into the PE channel. Due to similar excitation and emission properties, BB515, FITC, and Alexa Fluor® 488 cannot be used simultaneously. It is not recommended to use BB515 in cocktails that include Streptavidin conjugates as it may cause high background.

565211 Rev. 2
Format Details
Down Arrow Up Arrow
BB515
The BD Horizon Brilliant™ Blue 515 (BB515) dye is part of the BD Horizon Brilliant™ Blue family of dyes. This dye is a polymer fluorochrome with an excitation maximum (Ex Max) at 490-nm and an emission maximum (Em Max) of 515-nm. Driven by BD innovation, BB515 is designed to be excited by the blue laser (488-nm) and detected using an optical filter centered near 520-nm (e.g., 530/30-nm). BB515 reagents are significantly brighter than equivalent FITC or Alexa Fluor™ 488 reagents with less spillover into the PE detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BB515
Blue 488 nm
490 nm
515 nm
565211 Rev.2
Citations & References
Down Arrow Up Arrow
View product citations for antibody "565211" on CiteAb

Development References (6)

  1. Lin G-X, Yang X, Hollemweguer E, et al. Cross-reactivity of CD antibodies in eight animal species. In: Mason D. David Mason .. et al., ed. Leucocyte typing VII : white cell differentiation antigens : proceedings of the Seventh International Workshop and Conference held in Harrogate, United Kingdom. Oxford: Oxford University Press; 2002:519-523.
  2. Pace KE, Lee C, Stewart PL, Baum LG. Restricted receptor segregation into membrane microdomains occurs on human T cells during apoptosis induced by galectin-1. J Immunol. 1999; 163(7):3801-3811. (Clone-specific: Fluorescence microscopy, Functional assay, Immunofluorescence). View Reference
  3. Rabinowich H, Pricop L, Herberman RB, Whiteside TL. Expression and function of CD7 molecule on human natural killer cells. J Immunol. 1994; 152(2):517-526. (Biology). View Reference
  4. Reiter C. Cluster report: CD7. In: Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:341-342.
  5. Rosenzweig M, Marks DF, DeMaria MA, Connole M, Johnson RP. Identification of primitive hematopoietic progenitor cells in the rhesus macaque. J Med Primatol. 2001; 30(1):36-45. (Clone-specific: Flow cytometry). View Reference
  6. Zola H. Leukocyte and stromal cell molecules : the CD markers. Hoboken, N.J.: Wiley-Liss; 2007.
View All (6) View Less
565211 Rev. 2

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.