PE Mouse anti-Human CD157
Two-parameter flow cytometric analysis of CD157 expression on human peripheral blood leucocytes. Human blood was treated with BD Pharm Lyse™ (Cat. No. 555899) to lyse erythrocytes. The leucocytes were then stained with either PE Mouse IgG1, κ Isotype Control (Cat. No. 554680; Left Panel) or PE Mouse Anti-Human CD157 antibody (Cat. No. 564214; Right Panel). The two-parameter flow cytometric dot plots show the correlated expression patterns of CD157 (or Ig Isotype control staining) versus side light-scatter signals (SSC-A) for gated events with the forward and side light-scatter characteristics of viable leucocytes.  Flow cytometric analysis was performed using a BD™ Canto II Flow Cytometer System.
Two-parameter flow cytometric analysis of CD157 expression on human peripheral blood leucocytes. Human blood was treated with BD Pharm Lyse™ (Cat. No. 555899) to lyse erythrocytes. The leucocytes were then stained with either PE Mouse IgG1, κ Isotype Control (Cat. No. 554680; Left Panel) or PE Mouse Anti-Human CD157 antibody (Cat. No. 564214; Right Panel). The two-parameter flow cytometric dot plots show the correlated expression patterns of CD157 (or Ig Isotype control staining) versus side light-scatter signals (SSC-A) for gated events with the forward and side light-scatter characteristics of viable leucocytes.  Flow cytometric analysis was performed using a BD™ Canto II Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
BST1; Bone marrow stromal antigen 1; ADP-ribosyl cyclase 2; cADPr hydrolase
Human (QC Testing)
Mouse BALB/c IgG1, κ
Human CD157 Transfected Cell Line
Flow cytometry (Routinely Tested)
5 µl
AB_2738673
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  5. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  6. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
564214 Rev. 1
Antibody Details
Down Arrow Up Arrow
SY/11B5

The SY/11B5 monoclonal antibody specifically binds to CD157 which is also known as BST-1 (Bone marrow stromal antigen 1), BP-3/IF-7, Mo5, ADP-ribosyl cyclase 2, and cADPr hydrolase 2. CD157 is a 40-46 kDa glycophosphatidylinositol-linked cell membrane glycoprotein. It is an ectoenzyme that has both cyclic ADP-ribose hydrolase and ADP-ribosyl cyclase activities. CD157 is expressed as a homodimer by a variety of cell types including bone marrow stromal cells, granulocytes, monocytes, macrophages, dendritic cells, endothelial cells, and B and T cell progenitors. In addition to its ectoenzyme activities, CD157 reportedly functions as a receptor involved in neutrophil and monocyte adhesion, transendothelial migration and diapedesis and in tumor cell migration.

564214 Rev. 1
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
564214 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "564214" on CiteAb

Development References (5)

  1. Horenstein AL, Sizzano F, Lusso R, et al. CD38 and CD157 ectoenzymes mark cell subsets in the human corneal limbus. Mol Med. 2009; 15(3-4):76-84. (Clone-specific: Fluorescence microscopy, Immunofluorescence, Immunoprecipitation, Western blot). View Reference
  2. Malavasi F, Deaglio S, Funaro A, et al. Evolution and function of the ADP ribosyl cyclase/CD38 gene family in physiology and pathology. Physiol Rev. 2008; 88(3):841-886. (Biology). View Reference
  3. Ortolan E, Arisio R, Morone S, et al. Functional role and prognostic significance of CD157 in ovarian carcinoma. J Natl Cancer Inst. 2010; 102(15):1160-1177. (Clone-specific: Blocking, Functional assay, Inhibition, Western blot). View Reference
  4. Ortolan E, Vacca P, Capobianco A, et al. CD157, the Janus of CD38 but with a unique personality. Cell Biochem Funct. 2002; 20(4):309-322. (Biology). View Reference
  5. Quarona V, Zaccarello G, Chillemi A, et al. CD38 and CD157: a long journey from activation markers to multifunctional molecules. Cytometry B Clin Cytom. 2013; 84(4):207-217. (Biology). View Reference
View All (5) View Less
564214 Rev. 1

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.