Skip to main content Skip to navigation
BV421 Mouse Anti-Human CD126
BV421 Mouse Anti-Human CD126
Flow cytometric analysis of CD126 expression on human peripheral blood lymphocytes. Whole blood was stained with either BV421 Mouse IgG1, κ Isotype Control (Cat. No. 562438; dashed line histogram) or BV421 Mouse Anti-Human CD126 (Cat. No. 564163/566244; solid line histogram). Erythrocytes were lysed with Lysing Buffer (Cat. No. 555899). The fluorescence histograms were derived from gated events with the forward and side light-scattering characteristics of viable lymphocytes. Flow cytometric analysis was performed on a BD™ LSR II.
Flow cytometric analysis of CD126 expression on human peripheral blood lymphocytes. Whole blood was stained with either BV421 Mouse IgG1, κ Isotype Control (Cat. No. 562438; dashed line histogram) or BV421 Mouse Anti-Human CD126 (Cat. No. 564163/566244; solid line histogram). Erythrocytes were lysed with Lysing Buffer (Cat. No. 555899). The fluorescence histograms were derived from gated events with the forward and side light-scattering characteristics of viable lymphocytes. Flow cytometric analysis was performed on a BD™ LSR II.
Product Details
Down Arrow Up Arrow


BD Horizon™
Interleukin 6 Receptor alpha chain; IL-6R alpha; IL-6Rα
Human (QC Testing)
Mouse BALB/c IgG1, κ
CD126 Recombinant Protein
Flow cytometry (Routinely Tested)
5 µl
VI C63; IX 36
AB_2738634
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon BV421 under optimum conditions, and unconjugated antibody and free BD Horizon BV421 were removed.

Recommended Assay Procedures

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the Brilliant Stain Buffer (Cat. No. 563794/566349) or the Brilliant Stain Buffer Plus (Cat. No. 566385).                                        

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  5. Pacific Blue™ is a trademark of Molecular Probes, Inc., Eugene, OR.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. BD Horizon Brilliant Violet 421 is covered by one or more of the following US patents: 8,158,444; 8,362,193; 8,575,303; 8,354,239.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
564163 Rev. 2
Antibody Details
Down Arrow Up Arrow
M5

The M5 monoclonal antibody specifically binds to human CD126 which is also known as the alpha subunit of the human IL-6 Receptor (IL-6Rα). CD126 is an 80 kDa type I transmembrane glycoprotein, also known as gp80 and B cell stimulatory factor-2 (BSF-2) Receptor. The IL-6Rα subunit associates with the 130-160 kDa gp130 subunit (IL-6 Receptor β chain, CD130), that is shared with the receptor complexes for Leukemia Inhibitory Factor (LIF), Ciliary Neurotropic Factor (CNTF), Oncostatin M (OSM), IL-11, Cardiotropin 1 (CT-1) and possibly Neurotrophin-1/B Cell-Stimulating Factor 3 (NNT-1/BSF-3).  The IL-6Rα chain binds IL-6 with low affinity; however the association with CD130 stabilizes the IL-6/IL-6Rα complex resulting in the formation of a high affinity ligand-receptor complex. The IL-6Rβ chain mediates signal transduction. CD126 is expressed at high levels by activated and EBV-transformed B cells, plasma cells and myeloma cells and at lower levels by most leucocytes, epithelial cells, fibroblasts, hepatocytes and neural cells. IL-6Rα exists in soluble form in human serum. The serum levels of soluble IL-6Rα appear to elevate in pathological situations such as multiple myeloma, Grave's disease, juvenile chronic arthritis and HIV. The M5 antibody is directed against an epitope not involved in interactions of CD126 with IL-6 or CD130.

The antibody was conjugated to BD Horizon™ BV421 which is part of the BD Horizon Brilliant™ Violet family of dyes. With an Ex Max of 407-nm and Em Max at 421-nm, BD Horizon BV421 can be excited by the violet laser and detected in the standard Pacific Blue™ filter set (eg, 450/50-nm filter). BD Horizon BV421 conjugates are very bright, often exhibiting a 10 fold improvement in brightness compared to Pacific Blue conjugates.

564163 Rev. 2
Format Details
Down Arrow Up Arrow
BV421
The BD Horizon Brilliant Violet™ 421 (BV421) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This polymer-technology based dye has an excitation maximum (Ex Max) of 407-nm and an emission maximum (Em Max) at 423-nm. Driven by BD innovation, BV421 is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 420-nm (e.g., a 431/28-nm or 450/50-nm bandpass filter). BV421 is an ideal alternative for V450 as it is approximately ten times brighter with less spillover into the BV510/V500 detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV421
Violet 405 nm
407 nm
423 nm
564163 Rev.2
Citations & References
Down Arrow Up Arrow
View product citations for antibody "564163" on CiteAb

Development References (6)

  1. Autissier P, Liautard J, Brochier J, Gaillard JP. Activation of the gp130 signaling pathway by monoclonal antibodies directed against the gp130 molecule. Eur J Immunol. 1997; 27(3):794-797. (Biology). View Reference
  2. Brochier J, Liautard J, Jacquet C, Gaillard JP, Klein B. Optimizing therapeutic strategies to inhibit circulating soluble target molecules with monoclonal antibodies: example of the soluble IL-6 receptors. Eur J Immunol. 2001; 31(1):259-264. (Clone-specific: ELISA). View Reference
  3. Gaillard JP, Liautard J, Duperray C, Brochier J. mAb against human gp80 IL-6 receptor. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:1891-1894.
  4. Gaillard JP, Mani JC, Liautard J, Klein B, Brochier J. Interleukin-6 receptor signaling. I. gp80 and gp130 receptor interaction in the absence of interleukin-6.. Eur Cytokine Netw. 1999; 10(1):43-8. (Clone-specific: ELISA, Functional assay). View Reference
  5. Llinas L, Lazaro A, de Salort J, Matesanz-Isabel J, Sintes J, Engel P. Expression profiles of novel cell surface molecules on B-cell subsets and plasma cells as analyzed by flow cytometry. Immunol Lett. 2011; 134(2):113-121. (Biology). View Reference
  6. Tupitsyn N, Kadagidze Z, Gaillard JP, et al. Functional interaction of the gp80 and gp130 IL-6 receptors in human B cell malignancies. Clin Lab Haematol. 1998; 20(6):345-352. (Clone-specific). View Reference
View All (6) View Less
564163 Rev. 2

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.