Skip to main content Skip to navigation
FITC Mouse Anti-Human CD15
FITC Mouse Anti-Human CD15
Profile of peripheral blood granulocytes analyzed on a FACScan (BDIS, San Jose, CA)
FITC Mouse Anti-Human CD15
Multiparameter flow cytometric analysis of CD15 expression on human peripheral blood leucocyte populations. Human whole blood was stained with either FITC Mouse IgM, κ Isotype Control (Cat. No. 555583; Left Plot) or FITC Mouse Anti-Human CD15 antibody (Cat. No. 555401/560997; Right Plot). Erythrocytes were lysed with BD Pharm Lyse™ Lysing Solution (Cat. No. 555899). Bivariate pseudocolor density plots showing the correlated expression of CD15 [or Ig Isotype control staining] versus side light-scatter (SSC-A) signals were derived from gated events with the forward and side light-scatter characteristics of intact leucocyte populations. Flow cytometry and data analysis was performed using a BD FACSCanto™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
Profile of peripheral blood granulocytes analyzed on a FACScan (BDIS, San Jose, CA)
Multiparameter flow cytometric analysis of CD15 expression on human peripheral blood leucocyte populations. Human whole blood was stained with either FITC Mouse IgM, κ Isotype Control (Cat. No. 555583; Left Plot) or FITC Mouse Anti-Human CD15 antibody (Cat. No. 555401/560997; Right Plot). Erythrocytes were lysed with BD Pharm Lyse™ Lysing Solution (Cat. No. 555899). Bivariate pseudocolor density plots showing the correlated expression of CD15 [or Ig Isotype control staining] versus side light-scatter (SSC-A) signals were derived from gated events with the forward and side light-scatter characteristics of intact leucocyte populations. Flow cytometry and data analysis was performed using a BD FACSCanto™ Cell Analyzer System and FlowJo™ software. Data shown on this Technical Data Sheet are not lot specific.
商品详情
Down Arrow Up Arrow


BD Pharmingen™
Lewis X; Le-X; X-Hapten; SSEA-1; 3-FAL
Human (QC Testing)
Mouse IgM, κ
Human Mononuclear Cells
Flow cytometry (Routinely Tested)
20 µl
IV M141
AB_395801
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


准备和存储

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

商品通知

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
555401 Rev. 10
抗体详情
Down Arrow Up Arrow
HI98

The HI98 monoclonal antibody specifically reacts with 3-fucosyl-N-acetyllactosamine (3-FAL), a 220 kDa carbohydrate structure, also called X-hapten, SSEA-1, CD15 or Lewis X. This structure is found on a variety of cell surface glycolipids and glycoproteins. 3-FAL is expressed on >95% of granulocytes, including neutrophils and eosinophils, and to a varying degree on monocytes, but not on lymphocytes or basophils. CD15 plays a role in mediating phagocytosis, bactericidal activity and chemotaxis. This antibody is also suitable for staining formalin-fixed, paraffin-embedded tissue sections without pretreatment. Since the Abs are recognizing a carbohydrate epitope (3-fucosyl-N-acetyllactosamine) they also should work across species and not only for human.

555401 Rev. 10
格式详情
Down Arrow Up Arrow
FITC
Fluorescein (FITC) is part of the BD blue family of dyes. This is a small organic fluorochrome with an excitation maximum (Ex Max) at 494-nm and an emission maximum (Em Max) at 518-nm. FITC is designed to be excited by the Blue laser (488-nm) and detected using an optical filter centered near 520 nm (e.g., a 530/30-nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
FITC
Blue 488 nm
494 nm
518 nm
555401 Rev.10
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "555401" on CiteAb

研发参考 (8)

  1. Barclay NA, Brown MH, Birkeland ML, et al, ed. The Leukocyte Antigen FactsBook. San Diego, CA: Academic Press; 1997.
  2. Emanuel PD, Peiper SC, Chen Z, Sheng DC, Zuckerman KS. Specific inhibition of interleukin 3 bioactivity by a monoclonal antibody reactive with hematopoietic progenitor cells. Proc Natl Acad Sci U S A. 1990; 87(12):4449-4452. (Immunogen: Functional assay, Inhibition). 查看参考
  3. Knapp W. Flow cytometry studies with blind panel antibodies. In: Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:851-854.
  4. Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:1-1182.
  5. Koller U. Summary of immunohistology studies. In: Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:862-867.
  6. Lund-Johansen F, Olweus J, Horejsi V, et al. Activation of human phagocytes through carbohydrate antigens (CD15, sialyl-CD15, CDw17, and CDw65).. J Immunol. 1992; 148(10):3221-9. (Biology). 查看参考
  7. Shah VO, Safford MG, Terstappen LWMM, Loken MR. Quantitative comparison of myeloid antigens on peripheral blood lymphocytes, monocytes, neutrophils, eosinophils, and basophils. In: Knapp W. W. Knapp .. et al., ed. Leucocyte typing IV : white cell differentiation antigens. Oxford New York: Oxford University Press; 1989:855-858.
  8. Zola H. Leukocyte and stromal cell molecules : the CD markers. Hoboken, N.J.: Wiley-Liss; 2007.
查看所有文件 (8) 查看更少内容
555401 Rev. 10

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.